Key Features
- Measuring range from −200 °C to +1600 °C, depending on sensing element and protection tube grade
- Type K, J, N, S or B thermocouple, manufactured to EN 60584
- Mineral-insulated flexible sheath or thick-wall rigid protection tube in heat-resistant alloy or ceramic
- Wide choice of terminal heads, cable glands and process-connection fittings
- Optional head-mounted transmitter for 4–20 mA, 0–10 V or RS485 Modbus RTU output
- CE marked, suitable for industrial process environments
Technical Specifications
| Thermocouple type | K (NiCr-Ni), J (Fe-CuNi), N (NiCrSi-NiSi), S (Pt10Rh-Pt) or B (Pt30Rh-Pt6Rh), per EN 60584 |
| Measuring range | Type K: up to +1150 °C (standard MI version)
Type N: up to +1250 °C (MI version) Type S: up to +1600 °C (rigid ceramic protection tube) |
| Sheath / insulation | Mineral-insulated (MgO), Inconel 600 or Pyrosil-C alloy sheath, Ø 6 mm |
| Protection tube (rigid version) | Metallic: heat-resistant steel alloy, Ø 15/22 mm, length 300–1500 mm
Ceramic: rated 1200 °C or 1600 °C, Ø 10/15 mm, length 100–1500 mm, with stainless-steel support tube |
| Insertion length (L) | 300–2000 mm (mineral-insulated version), selectable to order |
| Process pressure | Up to approx. 1 bar (push-in, non-pressurised installation) |
| Terminal head | Type B — standard cast-aluminium head, DIN 43729
Type N — spherical head with hinged cover, cast aluminium, DIN 43729 Type S — stainless steel head for aggressive/corrosive environments, DIN 43729 |
| Output | Ceramic terminal block (direct wiring), or optional head-mounted transmitter: 4–20 mA, 0–10 V or RS485 Modbus RTU |
| Process connections | Weld-in bosses, compression fittings with external thread, or flange mounting |
| Ingress protection | IP54 (terminal head, standard version) |
| Compliance | EN 60584 (thermocouples), EN 61515 (mineral-insulated cable), CE marked |